Disabling the powerOffHelperVm flag is useful when the useSourcePasswordInHelperVm Converter Standalone worker flag is enabled. A volume-based conversion task stops responding if the source machine runs Windows and the cluster size for at least one of the source volumes is larger than 4KB If you submit For a list of supported systems, see the Guest Operating System Installation Guide. The converted source operating system must be supported for the destination VMware platform. this contact form

In the Data to Copy pane, select the volumes to copy and click Advanced. Now you can boot the machine. Workaround: In the vSphere Client Inventory, select the target virtual machine and click the Console tab to open the virtual machine console. Workaround: Wait for the configuration job to complete before you copy it.

Vcenter Converter Standalone Utility

Import of standalone VMware sources with a VMDK file greater than 2GB to a hosted destination that resides on a network share that does not support large files, fails If you Workaround: Remove the @ symbol from the datastore name and perform the conversion. [NEW] Submitting a job might fail with The specified parameter was not correct:"info.owner"message If Converter Standalone is installed The diskpart command prompt appears. (Optional) To list the available disks, enter list disk. For volume-based cloning of Acronis and StorageCraft, all volumes in the disk before the active and system volumes must be backed up.

These restrictions do not apply to Windows Vista guests because Windows Vista uses a UTF-8 encoded XML file to store the Microsoft sysprep parameters. Workaround: Connect directly to the destination ESX host instead of the vCenter Server. VMware Converter Standalone Integrated Worker VMware Converter Standalone Integrated Agent This behavior is not consistent and depends on the Windows version and patch level. Unable To Connect To The Network Share Admin$ Vmware Converter Linux An error message appears when you power on a destination virtual machine cloned from a live Windows Server 2003 source When you power on a destination virtual machine that is converted

This is due to incompatibility issues between the display driver used in the Linux guest and the display adapter of the target VMware virtual machine. At the minimum, change the root device name to reflect its new name in the target virtual machine. Apply the following patch to your ESX Server installation: ESX Server 3.0.2, Patch ESX-1002431; Updates to VMware-esx-vmx and VMware-esx-vmkernel; Fix For Detecting LSI Logic Controller, Support for PCI-X NICs on IBM Workaround: Do not stop any Converter Standalone services on the source machine during file-level cloning.

Workaround: Manually uninstall Converter Standalone agent from the source machine and create a new conversion task. Turn Off Simple File Sharing LILO boot loader is not supported for Linux sources You can convert powered-on machines that run Linux only if GRUB is installed as the boot loader on the source. Users with limited rights cannot install Converter Standalone 4.3 on Windows If you are logged in to Windows as a non-administrator user, the following error message is displayed while the InstallShield Workaround: For all cloning and conversion operations to ESX 4.0/ESXi 4.0 destinations, select SCSI controller type for the target virtual machine.

Vmware Converter Permission To Perform This Operation Was Denied

You cannot submit a conversion task if you change the destination type without applying changes to the networks settings In a Converter Standalone wizard, after you select a destination, if you https://kb.vmware.com/kb/2079864 Downgrade to another service pack. Vcenter Converter Standalone Utility If the connection port is different from the one that is being used for the already running conversion task, both tasks fail. Vmware Converter Agent Error 1603 Repeat steps 2-6 to mark another partition as inactive.

Thus any subsequent Linux P2V tasks cannot use the same static IP until this helper VM is powered off, or at least has its network interface disabled. weblink This is because the root device now has a different name (for example, it might have been changed to /dev/hda1). To restart Converter Standalone worker: Reboot the system or open the Services section in the Microsoft Management Console, find the VMware Converter Worker service and restart it. Converter Standalone 4.0.1 fails to install Converter Standalone remote agent during remote hot cloning During hot cloning of a remote source machine that has VMware Converter 3.x agent installed, Converter Standalone Download Vmware Converter Agent

Workaround: Do not use slash (/), backslash (\), colon (:), asterisk (*), question marks (?), quotation marks ("), or angle brackets (<>) in the destination virtual machine name. Virtual machines converted from Hyper-V virtual machine sources that run SLES 11 do not start up after conversion If you select to convert a powered-off virtual machine that resides on a Other volume managers, including but not limited to Veritas Volume Manager (VxVM), are not recognized. http://gmailpush.com/vmware-converter/vmware-converter-io-error.html Sparse files are not preserved during conversion of powered-on source machines that run Linux By default, Converter Standalone does not preserve sparse files on the source machine during Linux P2V conversion.

If the source is larger than the supported file size on the destination, the conversion tasks fails. Vmware Converter Unable To Contact The Specified Host The following error is displayed: Failed to create snapshot of source volume. This might also cause the conversion task to fail with a timeout error.

For example, if you are using non-ASCII characters in French or German, the limit for your destination virtual machine name might vary between 40 and 80 characters.

From the Exit menu, select Exit Saving Changes. You can search the Microsoft Web site for procedures on disabling the UAC depending on the source operating system. Converter Standalone does not support cloning powered-on Windows Server 2008 sources with FAT/FAT32 volume file system VSS under Windows Server 2008 does not support FAT/FAT32. Insufficient Permissions To Connect To Admin Vmware Converter If conversion is successful, the following error message related to the VMDK file might appear when you power on the destination virtual machine: Internal Inconsistency errors Workaround: In the main application

Error code: 2147754774 (0x80042316). If the hardware configuration of the source machine is modified while the Conversion wizard is open, you need to restart the conversion wizard if you want to view correct source details Workaround: Wait for the task to complete before selecting Copy as New in its pop-up menu. his comment is here Navigate to Computer Configuration > Windows Settings > Security Settings > Local Policies > Security Options.

Click Start to start the process. This dialog box does not represent an issue with the target machine. Workarounds: Select destination disk controller type as SCSI on the View/Edit Options page in Converter wizard. Stopping Converter Standalone processes during file-level cloning might cause the machine that runs the Converter Standalone Server service to restart During file-level cloning of source systems that run Windows XP or

Follow the on-screen instructions to complete the installation. The system returned: (22) Invalid argument The remote host or network may be down. For incremental images, up to 16 incremental backups are supported (ShadowProtect and Backup Exec System Recovery). Converter Standalone remote agent does not notify the user about uninstalling previous Converter 3.0.x installation on the same machine during remote hot cloning process If Converter Standalone 4.0.1 is converting a

Creating a conversion task to import a standalone VMware source with a VMDK file greater than 2GB from a network share that does not support large files, fails If you select Workaround: Restart the Windows Vista, Windows Server 2008, or Windows 7 machine and try installing Converter Standalone again. This is a known issue with Microsoft Windows Vista. Top of Page General If you try to convert a source physical or virtual machine to a managed destination by using thick provisioned disks with large empty spaces on them, the