Home > Return Code > Vsam Return Code Is 8 With Error Code Of 12

Vsam Return Code Is 8 With Error Code Of 12

Contents

Thanks, du [email protected] Posts: 3Joined: Mon Sep 06, 2010 2:03 pm Hasthanked: 0 time Beenthanked: 0 time Top Re: IDCAMS VERIFY & RETURN CODE 12 Top Re: IDCAMS VERIFY The error may be caused by such conditions as VSAM finding as unformatted record when expecting a formatted record, a volume containing data other than that expected, or an I/O error. This is probably a system error. The extent information in the catalog entry may not agree with the extent information in the volume's VTOC. http://gmailpush.com/return-code/vsam-return-code-is-8-with-error-code-of-116.html

Therefore, the file status key may not always be a numeric value that is easy to display. X'11' 017 Return Code=08 Action=OPEN The address in an ASSGN statement for a VSAM volume was set to IGN. It's about the business of doing business and looking good in the process. This document and the links to other documents are intended to provide a greater awareness of the Data Management and Application Processing alternatives. https://www.ibm.com/support/knowledgecenter/SSLTBW_1.13.0/com.ibm.zos.r13.idat300/rmrrc.htm

Vsam Return Code 28

Return Code=08 Action=OPEN The symbolic unit in the EXTENT statement is invalid. Only DTFPH may be used with NOCIFORMAT files. PROGRAMMER ACTION: Change your program to build the resource pool before attempting to open any ACB that uses local shared resoures. Make sure that programmers logical units are available and rerun the job.

Rerun the job. The ascending key requirements of successive record key values has been violated or the prime record key value has been changed by a COBOL program between successful execution of a READ Your cache administrator is webmaster. Vsam Extended Return Code Can Contain The Message Message 42261 will be issued at end-of-job step for this file.

MAXIMUM CONDITION CODE WAS 12 ******************************** BOTTOM OF DATA ********************************IEF237I JES2 ALLOCATED TO SYSOUT IEF237I JES2 ALLOCATED TO SYSPRINT IEF237I JES2 ALLOCATED TO SYSIN IEF142I ASNPG57V VERIFY - STEP WAS EXECUTED Vsam Return Code 168 PROGRAMMER ACTION: Change your program to use managed SAM to access the file, or change the DLBL statement to specify a file other than SAM ESDS. Return Code=08 Action=Request VSAM received a return code from the LOCK macro indicating that there is no space in the lock table to make a lock entry. PROGRAMMER ACTION: Take a system dump, contact your IBM Support Center and have the dump output, SYSLOG output, and a copy of the job stream available for problem determination.

X'74' 116 Return Code=04 Action=OPEN You tried to open a file that was not successfully closed the last time it was opened for output. Vsam File Status 93 The previous time the file was opened was the initial load of the file, and SPEED was specified. The request cannot be fulfilled by the server The request cannot be fulfilled by the server File Status Keys Return Codes for Data Files & VSAM Table of Contents v-16.01.01 Refer to the section for Status-Key-1 being equal to "1" for additional information based on Status-Key-2. 2Invalid Key, an attemprt to access a file failed because the requested key is not

Vsam Return Code 168

The file has been opened successfully. http://theamericanprogrammer.com/programming/vsamerr.shtml X'2C' 044 Return Code=08 Action=Request The work area you have supplied (in the AREA = addr operand for the RPL) is not large enough for the requested data record. Vsam Return Code 28 Return Code=08 Action=Request VSAM detected a record out of sequence in a key-sequenced or relative-record file (possibly a duplicate key or record number). File Status 37 In Vsam DISP=NEW was specified for an input file.

For sequential processing, this error code is set on for only the first record of the CI. news The second character is known as status-key-2 additional detail. If the problem persists print the dump from the SYSDMP. (Refer to VSE/VSAM Access Method Services Logic for ivterpretation of the IDUMP output.) Contact your IBM Support Center and make IDUMP X'10' 016 Return Code=00 Action=Request A control-area split occurred because there was not enough space to make an index entry in a sequence set-record. File Status 39

X'80' 128 Return Code=08 Action=OPEN The DLBL statement for the file or catalog is missing, or the file name specified in that statement does not match the name of the ACB. Such a file is really a model and not to be opened. DISP=NEW was specified for a file using local shared resources. have a peek at these guys A GETVIS failure, or a failure to load a VSAM phase occurred.

You requested a programmer logical unit that was not system generated (IOTAB xxPRG). Vsam Logical Error 08 On Output ALT INDX' 003500 WHEN '04' DISPLAY 'READ, WRONG LENGTH RECORD' 003600 WHEN '05' DISPLAY 'OPEN, FILE NOT PRESENT' 003700 WHEN '07' DISPLAY 'CLOSE OPTION INCOMPAT FILE DEVICE' 003800 DISPLAY 'OPEN IMPLIES Return Code=08 Action=Request An ERASE marco is issued for an entry-sequenced file (directly or via a path) or for a file for which control-interval processing has been specified.

PROGRAMMER ACTION: Restructure your program so that fewer files are open concurrently.

PROGRAMMER ACTION: Ensure that your program provides a properly generated ACB and does not inadvertenly overlay the ACB before opening it. The maximum number of extensions for the file has been exceeded. PROGRAMMER ACTION: Because this information was collected during OPEN processing, it cannot be printed. Vsam File Status 92 Return Code=08 Action=Request VSAM encountered end of file (during sequential retrieval), or the search argument is greater than the highest existing key (or relative record number) in the file.

One of the following situations may have occurred. X'42' 066 Return Code=08 Action=OPEN An attempt was made to open a DTF with file characteristecs that are incompatible with the file's cdharacteristics in the VSAM catalog. Comments or Feedback This document was created and is copyrighted and maintained by SimoTime Technologies. http://gmailpush.com/return-code/vsam-return-code-08-error-code-152.html If the error occurred although the correct volume was mounted and there was no job control error, restore the catalog by using a backup copy or the catalog recovery function.

GET UPD ADR is requested but ADR was not specified on the ACB when the SHAREOPTIONS(4)KSDS was opened. If Catalog Check finds no error, the problem was due to insufficient storage. This code can also indicate that you attempted to load an empty file (using REPRO REPLACE) when the input file contained duplicate records. X'60' 096 Return Code=04 Action=OPEN The file to be opened for input was found to be unusable because catalog recovery for this file failed.

Too many files open simultaneously (Micro Focus). 15 Too many indexed files open (Micro Focus). 16 Too many device files open (Micro Focus). 17 Record error: probably zero length (Micro Focus). CONDITION CODE IS 12 X'CC' 204 Return Code=08 Action=Request The program issued a PUT to insert a record while in backward mode. PROGRAMMER ACTION: Use Appendix B to determine the cause of the error specified in message 4A371 and take the recommended action.

Return Code=08 Action=Request VSAM encountered an invalid relative-record number. The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies. For recoverable catalogs, VSAM always assigns a programmer logical unit for each CRA. The error may be caused by an invalid key or the sequence of processing for a valid key.

The Catalog Check Service Aid is documented in VSE/VSAM Programmer's Reference. Return Code=0C Action=Request VSAM failed to write index-set records of an index. X'46' 070 Return Code=08 Action=OPEN An invalid file-id was detected during implicit define or implicit delete. Instruct the operator to ensure that the device on which the volume mounting is done is in "up" status and unreserved before replying `NEWPAC'.

http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/IEA2M660/11.551?SHELF=&DT=20050804102553&CASE= Back to top Display posts from previous: All Posts1 Day7 Days2 Weeks1 Month3 Months6 Months1 YearOldest FirstNewest First MVSFORUMS.com Forum Index -> Data Management All times are GMT -