Home > Return Code > Vsam Logical Error 12

Vsam Logical Error 12

Contents

The last I/O statement executed for the file, before the execution of a DELETE or REWRITE statement, was not a READ statement. 44 A boundary violation exists. Explore The ASCII and EBCDIC Translation Tables. Refer to the section for Status-Key-1 being equal to "1" for additional information based on Status-Key-2. 2Invalid Key, an attemprt to access a file failed because the requested key is not Click to share on Facebook (Opens in new window)Click to share on LinkedIn (Opens in new window)Click to share on Twitter (Opens in new window)Click to share on Google+ (Opens in this content

Following are the common file status codes with their description which will help you to resolve the issues: CodeDescription 00Operation completed successfully 02Non-Unique Alternate Index duplicate key found 04Invalid fixed length Company Overview Founded in 1987, SimoTime Technologies is a privately owned company. I am getting VSAM open error. You tried to retrieve a record with a relative record number that corresponds to an empty slot (for an RRDS).

Vsam Status Codes

Stay connected Facebook Twitter Google+ LinkedIn RSS Feed Archives Archives Select Month October 2016 September 2016 August 2016 July 2016 June 2016 April 2016 March 2016 December 2015 November 2015 October If you have any questions, suggestions, comments or feedback please call or send an e-mail to: [email protected] We appreciate hearing from you. We appreciate hearing from you. So check if the output vsam cluster is defined with reuse option Hope this helps...

Explore the COBOL Connection for more examples of COBOL programming techniques and sample code. Comments or Feedback This document was created and is copyrighted and maintained by SimoTime Technologies. Either there is not enough space left to make the secondary allocation or you attempted to increase the size of a data set while processing SHROPT=4 and DISP=SHR. 036(24) KeyRangeswere specified Vsam Return Code 168 PreviousMost Common JCL Error Codes NextVSAM Open Error Codes Be the first to comment Leave a Reply Cancel reply Your email address will not be published.CommentName * Email * Website Prove

Primary File Status The first character of the File-Status-Key is known as status-key-1; the second character is known as status-key-2. You get VSAM logical errors and, therefore, VSAM feedback codes if the following occurs: SAS cannot detect the error in advance (for example, user lockout). Can someone one throw some light on these and provide any links to manuals related to these? go

I am using Changeman. Vsam Rpl Feedback Codes But I am not sure. We have a team of individuals that understand the broad range of technologies being used in today's environments. In this case, the physical size of the new record is allowed to be smaller than that of the record being replaced. 46 A sequential READ operation has been tried on

Vsam Logical Error 08 On Output

Back to top kolusuSite AdminJoined: 26 Nov 2002Posts: 11556Topics: 74Location: San Jose Posted: Tue May 22, 2007 6:51 pm Post subject: chandrasekhar.a, Check this for pdf manual of BMc's Log Master http://ruifeio.com/2011/12/11/vsam-logical-error-codes/ Many vendors take advantage of the x"00' to x'FF' (or 0-255) binary value. Vsam Status Codes If you specify the RRN of an existing but empty slot, the feedback code is 16 instead of 192 (for an RRDS). Vsam Return Code 28 For Shared Resources, buffer pool is full. 016(10) Record not found. 020(14) Record already held in exclusive control by another requester. 024(18) Record resides on a volume that cannot be mounted.

Cheers Kolusu_________________Kolusu - DFSORT Development Team (IBM) DFSORT is on the Web at: www.ibm.com/storage/dfsort Back to top BitheadAdvancedJoined: 03 Jan 2003Posts: 550Topics: 23Location: Michigan, USA Posted: Fri Mar 17, 2006 2:53 news Alternate indexes are incorrectly defined (Key length or position, duplicates or sparse parameters). 2. I had never run across these executables. This can be caused by issuing a read after the end-of-file has been reached during sequential processing. 9149 95 Wrong open mode or access mode for REWRITE/ DELETE. 9150 96 Program Vsam Extended Return Code Can Contain The Message

Other possible causes are: 1. Explore The Micro Focus Web Site via Internet Connect for more information about products and services available from Micro Focus. Trying to open a file that does not exist.May need to map the COBOL file name to the physical file name. (Micro Focus, refer to the ASSIGN(EXTERNAL) directive). 37 An OPEN have a peek at these guys We reserve the right to make changes without notice at any time.

Use this when there is RC 8 in vsam-extended-return-code 004 Read past end of file 008 Duplicate key 012 Key sequence error 016 Not found 020 Control interval in use Vsam Open Return Code Is 100 Any help will be really great!! This includes the smallest thin client using the Internet and the very large mainframe systems.

The value indicates the status of that request.

It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. Instead, SAS prints a message that describes the error on the SAS log and stops the DATA step. DO you know how to change old parameters. File Status 37 In Vsam SAS does not know what action to take (for example, record not found).

SimoTime Services has experience in moving or sharing data or application processing across a variety of systems. Enter your email address here Advertisement Home About Me Sitemap Contact Me Copyright © 2016 Rui Miguel Feio Send to Email Address Your Name Your Email Address Cancel Post was not We have made a significant effort to ensure the documents and software technologies are correct and accurate. http://gmailpush.com/return-code/vsam-io-error-28.html SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose.

But i know they belong to BMC utilities. This condition indicates that an attempt has been made to write beyond the externally defined boundaries of a sequential file. 35 An OPEN operation with the I-O, INPUT, or EXTEND phrases All Rights Reserved. All rights reserved.

Indicates a sequence error. Copyright © 1987-2016SimoTime TechnologiesAll Rights Reserved File Status Key Overview The ANS/85 standard provides for a two-byte File-Status-Key. The codes in this list represent decimal values. For an OPEN or CLOSE statement with the REEL/UNIT phrase the referenced file is a non-reel/unit medium. 08 Attempted to read from a file opened for output. 09 No room in

Back to top Display posts from previous: All Posts1 Day7 Days2 Weeks1 Month3 Months6 Months1 YearOldest FirstNewest First MVSFORUMS.com Forum Index -> Utilities All times are GMT - 5 Hours The following tables contain file-status-key content that may be set by Micro Focus COBOL (Mainframe Express or Net Express) or an IBM Mainframe System (MVS, OS/390 or ZOS). Back to top kolusuSite AdminJoined: 26 Nov 2002Posts: 11556Topics: 74Location: San Jose Posted: Fri Mar 17, 2006 12:27 pm Post subject: vak255, Please post the exact error message it which starts Notify me of new posts by email.

Software Agreement and Disclaimer Permission to use, copy, modify and distribute this software, documentation or training material for any purpose requires a fee to be paid to SimoTime Technologies. Note:A SimoTime License is required for the items to be made available on a local system or server. There is more to making the Internet work for your company's business than just having a nice looking WEB site. thanks Bithead, but I am getting the same error.problem with RRDS o/p file Back to top vak255IntermediateJoined: 10 Sep 2004Posts: 381Topics: 78 Posted: Sat Mar 18, 2006 1:46 am Post subject:

OUTPUT FILE CWPDDIO OPENMEM ERROR, RETURN CODE=4814 OPENMEM error ? The DB2 field type for this field is of type DOUBLE FLOAT and is present in the file from position 1 to 8. You can delete and re-define the cluster once again with REUSE option. The documentation and software were developed and tested on systems that are configured for a SimoTime environment based on the hardware, operating systems, user requirements and security requirements.

A good place to start is The SimoTime Home Page via Internet Connect for access to white papers, program examples and product information.