Home > Return Code > Vsam I O Error On Dataset

Vsam I O Error On Dataset

Contents

Possible causes:Attempting to WRITE or REWRITE a record that is larger than the largest, or smaller than the smallest record allowed by the RECORD IS VARYING clause of the associated file.Attempting S117 - AN I/O ERROR OCCURRED DURING A BSAM CLOSE TYPE=T MACRO. The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies. S306 - 10 - A LOAD MACRO REQUESTED A MODULE REQUIRING PAGE ALIGNMENT WITH GLOBAL=(YES,F) SPECIFIED. this content

Once the fee is received by SimoTime the latest version of the software, documentation or training material will be delivered and a license will be granted for use within an enterprise, S0B0 - 18 - QMNGRIO MACRO WAS ISSUED WITH BOTH OR NEITHER OF THE READ AND WRITE BITS SET. SimoTime Services has experience in moving or sharing data or application processing across a variety of systems. S013 - 44 - AN OPEN MACRO WAS ISSUED FOR A DATASET ON A DIRECT ACCESS DEVICE FOR WHICH CHAINED SCHEDULING WAS SPECIFIED, BUT THE BUFFER CONTROL BLOCK ADDRESS WAS 0.

How To Solve Vsam I/o Return Code Is 28

S305 - 1C - ZERO LENGTH WAS NOT SPECIFIED ON A SUBPOOL FREEMAIN. S112 - 13 - DCB DOES NOT POINT TO A VALID DEB. THE TWO LOW-ORDER BYTES OF REGISTER-15 CONTAIN A HEXIDECIMAL REASON CODE.- 0000 - A HALT NET,CANCEL COMMAND HAS BEEN PROCESSED.- 10F1 - THE ACF/VTAM STAE RETRY ROUTINE ISSUED AN ABEND 0A9

CORRECT THE RECFM TO FB, OR MAKE LRECL AND BLKSIZE EQUAL. S204 - 00 - (00 IS THE ONLY POSSIBLE RETURN CODE ASSOCIATED WITH S204) GETMAIN ERROR. Indicates a boundary violation. Vsam Open Return Code Is 160 Terms of Service | Privacy Policy | Contact×OKCancel Τα cookie μάς βοηθούν να σας παρέχουμε τις υπηρεσίες μας. Εφόσον χρησιμοποιείτε τις υπηρεσίες μας, συμφωνείτε με τη χρήση των cookie από εμάς.Μάθετε

For the COBOL environment if the FILE STATUS clause is specified in the FILE-CONTROL entry, a value is placed in the specified status key (the 2-character data item named in the Vsam Return Code ONLY WRITE LOAD (WL) IS ALLOWED. S233 - 24 - THE SPECIFIED ASID PARAMETER WAS SYNTACTICALLY INVALID. http://www.ibm.com/support/knowledgecenter/SSLTBW_2.2.0/com.ibm.zos.v2r2.ieam600/bb3351.htm The ascending key requirements of successive record key values has been violated or the prime record key value has been changed by a COBOL program between successful execution of a READ

Glossary of Terms Explore the Glossary of Terms for a list of terms and definitions used in this suite of documents and white papers. Vsam Return Code 168 S013 - 60 - AN OPEN MACRO WAS ISSUED FOR A DATASET WITH A DCB SPECIFYING RECFM=F, AND BLKSIZE WAS NOT EQUAL TO LRECL. This document and the links to other documents are intended to provide a greater awareness of the Data Management and Application Processing alternatives. ACCEPTABLE TYPES ARE ADD, DELETE, VERIFY, AND PURGE.

Vsam Return Code

There is more to making the Internet work for your company's business than just having a nice looking WEB site. S013 - 70 - AN OPEN MACRO WAS ISSUED FOR A DATASET ON MAGNETIC TAPE. How To Solve Vsam I/o Return Code Is 28 VALUES OTHER THAN 0 INDICATE A POINETR TO THIS DEB ALREADY EXISTS IN THE DEB TABLE. Vsam Open Return Code Is 232 S30A - 10 - LSQA STORAGE IS NOT IN THE SUBPOOL SPECIFIED.

S113 - 28 - OPEN ATTEMPT FOR CONCATENATED VSAM USING A DCB. news An attempt has been made to access a record, identified by a key, and that record does not exist in the file. The last I/O statement executed for the file, before the execution of a DELETE or REWRITE statement, was not a READ statement. 44 A boundary violation exists. S213 - 48 - OPEN DETECTED A BAD RETURN CODE FROM THE EXTENDED CACHE ATTRIBUTE FACILITY. Vsaminit

S013 - A4 - A DCB WAS OPENED FOR A SYSIN OR SYSOUT DATASET BUT THE DSORG WAS NOT SPECIFIED AS PS. EITHER OPEN SPECIFIED UPDAT OR RDBACK, OR THE POINT MACRO FUNCTION WAS SPECIFIED IN MACRF=RP OR WP. S0E0 - 34 - A PR INSTRUCTION WAS ISSUED AGAINST A LINKAGE STACK ENTRY THAT HAS THE UNSTACK SUPPRESSION BIT SET. have a peek at these guys S013 - 58 - AN OPEN MACRO WAS ISSUED FOR A PAPER TAPE DATASET AND CONCATENATION WITH UNLIKE ATTRIBUTES WAS SPECIFIED.

LIST NOT ON A FULLWORD BOUNDARY OR NOT IN JOB STEP'S STORAGE. Idc3351i S013 - 3C - A SEQUENTIAL DATASET WAS OPENED FOR INPUT OR OUTPUT, BUT THE BUFFER CONTROL BLOCK ADDRESS WAS 0. S305 - 0C - CSA STORAGE IS NOT IN THE SUBPOOL SPECIFIED.

S053 - A PROGRAM MADE A PC/AUTH REQUEST BUT AN ERROR PREVENTED NORMAL COMPLETION.

The Recording Mode is Variable or Fixed or not defined the same as when the file was created. 3. http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/IEA2M660/11.551?SHELF=&DT=20050804102553&CASE= Thanks, Phantom Back to top vkphaniIntermediateJoined: 05 Sep 2003Posts: 483Topics: 48 Posted: Tue Oct 04, 2005 2:13 am Post subject: Hi Phantom, Thanks for the help. S0FB - A TRANSLATION EXCEPTION HAS OCCURRED. Vsam Open Error A0 S20A - 00 - (00 IS THE ONLY POSSIBLE RETURN CODE ASSOCIATED WITH S20A) GETMAIN ERROR.

S024 - AN ABNORMAL TERMINATION OCCURRED IN PRINT SERVICES FACILITY. S02C - AN ERROR OCCURRED IN JES2 SUPPORT OF AN FSS ADDRESS SPACE. S013 - BC - A SYSIN OR SYSOUT DCB WAS OPENED WITH INVALID OPTIONS. http://gmailpush.com/return-code/vsam-io-error-28.html IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE S240 OPERAND FOR MORE SPECIFIC INFORMATION: H ABEND O(S240-RC) S240 - 04 - A RDJFCB MACRO INSTRUCTION WAS ISSUED,

S013 - A8 - AN INVALID RECORD FORMAT WAS REQUESTED FOR A SYSIN OR SYSOUT DATASET. (RECFM=D, VS, OR VBS ARE INVALID FOR SYSIN) S013 - AC - A QSAM OPEN S128 - AN INVALID ADDRESS LIST WAS SPECIFIED FOR AN EXTRACT MACRO. BEFORE THE DEB POINTER CAN BE ADDED TO THE TABLE, THE DEB ITSELF MUST BE QUEUED ON THE CURRENT TCB DEB CHAIN. BAD DAT TABLES OR WRONG STO ADDRESS.

S002 - 30 - ONE OF THE FOLLOWING IS TRUE:- A READ WAS ISSUED BUT THE LENGTH TO BE READ WAS ZERO.- A QSAM PUT WITH MOVE MODE WAS ISSUED FOR DURING THE EXECUTION OF OPEN IT WAS DETECTED THAT THE BLOCKSIZE WAS LARGER THAN THE PRIMARY EXTENT. Top of Page | Home | Books for Computer Professionals | Privacy | Terms | | Site Map and Site Search | Programming Manuals and Tutorials | The S029 - LINES EXCEEDED S02A - JES2 FOUND THAT DATA MANAGEMENT CONTROL BLOCKS OR THE JES2 UBUF CONTROL BLOCK WAS NO LONGER VALID DURING EXECUTION OF A DATA MANAGEMENT REQUEST FOR

S021 - A CALLER OF THE ASCBCHAP ROUTINE PASSED TO ASCBCHAP AN ASCB ADDRESS THAT HAD BITS SET TO ONE IN ITS HIGH ORDER BYTE. S013 - 50 - AN OPEN MACRO ISSUED FOR A DATASET ALLOCATED TO A PRINTER DID NOT HAVE OUTPUT SPECIFIED AS AN OPEN OPTION. S0C7 - DATA EXCEPTION - DECIMAL DATA IS INCORRECT OR IMPROPERLY OVERLAPPED OR NOT VALIDLY INITIALIZED.POSSIBLE CAUSE- SUBSCRIPT ERROR, REFERENCED BEYOND TABLE- COBOL - WORKING STORAGE NOT INITIALIZED- BAD DATA, SHOULD S013 - 7C - AN OPEN MACRO WAS ISSUED FOR AN OPTICAL CHARACTER READER DATASET, BUT THE LRECL PARAMETER IN THE DCB WAS ZERO.

S115 - SVC 21 (STOW) ERROR. S206 - THE ADDRESS OF THE PARAMETER LIST, OR ONE OF THE PARAMETERS PASSED TO A LINK, LOAD, XCTL, OR DELETE MACRO WAS INVALID. S013 - E4 - THE LIMIT OF 123 EXTENTS FOR A CONCATENATED PARTITIONED DATA SET HAS BEEN EXCEEDED. (USED TO BE 256 EXTENTS?) S013 - E8 - THE OPEN VERIFICATION FUNCTION This document may be used to assist as a tutorial for new programmers or as a quick reference for experienced programmers.

In most installations, this is not the common practice. THE PDS IS ALREADY OPEN IN THIS CONDITION. AN OPTION WAS SPECIFIED WHICH IS NOT SUPPORTED BY MVS.