Home > Return Code > Vsam Error Message

Vsam Error Message

Contents

The number of significant digits in the relative record number is larger than the size of the relative key data item described for that file. Could also indicate an out of memory situation. 9002 02 File not open when access tried. 9003 03 Serial mode error. 9004 04 Illegal file name.Micro Focus, the COBOL file name Extended File Status, nnn-xx The first character of the File-Status-Key is known as status-key-1. The INQUIRE FILE command failed; refer to the reported response and response2 fields for more information. this content

Refer to the section for Status-Key-1 being equal to "9" for additional information based on Status-Key-2. If you have any questions, suggestions, comments or feedback please call or send an e-mail to: [email protected] We appreciate hearing from you. But I think you may need to know why files are being left open. Explore the COBOL Connection for more examples of COBOL programming techniques and sample code. https://www.ibm.com/support/knowledgecenter/SSLTBW_1.13.0/com.ibm.zos.r13.idat300/rmrrc.htm

Vsam Return Codes

CICS? and for the 062:Specific Information for This Return CodeVERIFY has been successfully run by OPEN to determine the end of a VSAM data set which was not previously closed successfully.System Action: In the Code tags, please. INQ FI(CUSTOMER) STATUS: RESULTS - OVERTYPE TO MODIFY Fil(CUSTOMER) Vsa Clo Ena Rea Upd Add Bro Del Sha Rea = Read attribute Upd = Update attribute Add = Add attribute Del

What I cannot remember is whether these messages will be issued for the VERIFY. The error may be caused by an invalid key or the sequence of processing for a valid key. This document may be used to assist as a tutorial for new programmers or as a quick reference for experienced programmers. Vsam File Status 93 CONNX attempted to open the target file for update processing, but the file attributes do not permit read, add, delete, or update access.

Job is executing fine. File Open Error 06: CICS SET FILE CLOSED WAIT CONNX issued an unsuccessful CICS SET FILE CLOSED WAIT command against the target file. They appear on the JOB log. 004(04) Read past end of file 008(08) You attempted to store a record with a Duplicate Key, or there is a duplicate record for an http://www.ibm.com/support/knowledgecenter/SSGMCP_5.2.0/com.ibm.cics.sfr.doc/topics/mqsiagentvsamerrors.html Explore the non-Relational Data Connection for more examples of accessing methodologies and coding techniques for Data Files and VSAM Data Sets.

Note that it is not valid to use VERIFY on a linear data set. Vsam Return Code 160 File statuses should always be checked, and appropriate action taken when you get an unexpected result. If the data set was opened for output, then the catalog will be updated when the data set is successfully closed. Summary This document provides a summary of the two-byte File-Status-Key (sometimes referred to as file return code or file status code).

Vsam Return Code 168

BillyBoyo Global moderator Posts: 3738Joined: Tue Jan 25, 2011 12:02 am Hasthanked: 22 times Beenthanked: 255 times Top Re: VSAM Error/Warning messages by gopal_NKP » Tue Sep 06, 2011 4:52 The VERIFY command can be issued via IDCAMS so just add a step at the front of the job to verify the datasets. Vsam Return Codes What this all means is that the last process to open the VAM file did not successfully close it. Vsam Return Code 28 Possible causes:For a READ statement the key value for the current key is equal to the value of that same key in the next record in the current key of reference.For

Internet Access Required The following links will require an internet connection. news It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. You can check them in the same way that you check VSAM files. Attempt has been made to store a record that would create a duplicate key in the indexed or relative file OR a duplicate alternate record key that does not allow duplicates. Vsam Extended Return Code Can Contain The Message

The function delivered in this version is based upon the enhancement requests from a specific group of users. Please tell me, how to add a verify step to check these. (with example if possible)once again, thanks for your help.thanksvgl gopal_NKP Posts: 22Joined: Fri Feb 25, 2011 11:47 am Therefore, the file status key may not always be a numeric value that is easy to display. http://gmailpush.com/return-code/vsam-error-08.html This might point to a problem.

As Robert has said, the system has made the file usable already.However, whatever was using the file before your program ran left the file open for some reason. Vsam Logical Error 08 On Output We have a team of individuals that understand the broad range of technologies being used in today's environments. Software Agreement and Disclaimer Permission to use, copy, modify and distribute this software, documentation or training material for any purpose requires a fee to be paid to SimoTime Technologies.

VSAM Logical error codes These codes indicate VSAM errors.

Refer to the section for Status-Key-1 being equal to "1" for additional information based on Status-Key-2. 2Invalid Key, an attemprt to access a file failed because the requested key is not Refer to the response and response2 codes for this message. File Open Error 03: CICS INQUIRE FILE CONNX issued a CICS INQUIRE FILE against the target file to determine its OPEN and ENABLED status. Vsam Return Code 232 Refer to the response and response2 codes for this message.

Top of Page | Home | Books for Computer Professionals | Privacy | Terms | | Site Map and Site Search | Programming Manuals and Tutorials | The The American Programmer Home Books on Mainframe Programming Mainframe Manuals and Tutorials System Abend codes, Sqlcodes, VSAM/QSAM codes Mainframe Abend Codes. VSAM Explore How to Obtain and Display the File Status after attempting to access a data file or VSAM data set. check my blog Please try the request again.

SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose. This is usually caused by a conflict with record-length, key-length, key-position or file organization. Refer to the section for Status-Key-1 being equal to "2" for additional information based on Status-Key-2. 3Permanent Error, usually caused by a limit in the logical processing or a difference in Many vendors take advantage of the x"00' to x'FF' (or 0-255) binary value.

The second character is known as status-key-2 additional detail. The first group of documents may be available from a local system or via an internet connection, the second group of documents will require an internet connection. This document and the links to other documents are intended to provide a greater awareness of the Data Management and Application Processing alternatives. Explore The Micro Focus Web Site via Internet Connect for more information about products and services available from Micro Focus.

Unless you can identify which process (started task, TSO user, batch job, or whatever) did this, you have absolutely no hope of completely resolving this.Furthmore, why do you care? Alternatively a START or READ operation has been tried on an optional input file that is not present. 24 Relative and indexed files only. Google can help with the messages. Refer to the section for Status-Key-1 being equal to "3" for additional information based on Status-Key-2. 4Logic Error, a program is attempting a file access function in an improper sequence or

If they are then you have a lot of research to do to find out what programs/jobs left these datasets in this state. Your cache administrator is webmaster. The first character of the File-Status-Key is known as status-key-1 and defines a group or category. For files with variable-length records the minimum and maximum record lengths for the actual file may not match the minimum and maximum record lengths used by the program 41 An OPEN

The following tables contain file-status-key content that may be set by Micro Focus COBOL (Mainframe Express or Net Express) or an IBM Mainframe System (MVS, OS/390 or ZOS). In the world of programming there are many ways to solve a problem. Ask the CICS administrator to verify that the target file exists; also request that the CONNX CICS/VSAM server transaction (NXS0) and/or the CICS userid be authorized to execute the CICS INQUIRE Primary File Status The first character of the File-Status-Key is known as status-key-1; the second character is known as status-key-2.

I want to prevent those messages. If so, you would have got a non-zero file status on the OPEN for the file, which would mean you are not checking the file status for the OPEN.