Vsam File Error Code 92

Contents

MVSFORUMS.comA Community of and for MVS Professionals FAQ Search Quick Manuals Register Profile Log in to check your private messages Log in vsam file status 92 while reading. All Rights Reserved.   Sitemap Share Here.. These attributes include the organization of the file (sequential, relative, or indexed), the prime record key, the alternate record keys, the code set, the maximum record size, the record type (fixed The combinations of possible values and their meanings are shown below. this content

All Rights Reserved. The last I/O statement executed for the file, before the execution of a DELETE or REWRITE statement, was not a READ statement. 44 A boundary violation exists. Refer to the section for Status-Key-1 being equal to "9" for additional information based on Status-Key-2. Indicates a duplicate key condition.

Vsam File Status 92 While Writing

This includes the smallest thin client using the Internet and the very large mainframe systems. Explore The ASCII and EBCDIC Translation Tables. The preceding READ statement caused an at end condition.4 - 7 The execution of a READ statement was attempted on a file not open in the input or I-O mode.4 - Therefore, adjustments may be needed to execute the jobs and programs when transferred to a system of a different architecture or configuration.

ie FD section.Make sure that it matches the listcat info of the vsam file. 2. Refer to the section for Status-Key-1 being equal to "0" for additional information based on Status-Key-2. 1End of File, attempting to read beyond the end of the file. The preceding READ statement caused an at end condition.4 - 7 The execution of a READ statement was attempted on a file not open in the input or I-O mode.4 - File Status 39 An attempt has been made to access a record, identified by a key, and that record does not exist in the file.

For line sequential files this refers to the physical size of the record, that is after space removal, tab compression and null insertion. Vsam File Status 97 Extended File Status, nnn-xx The first character of the File-Status-Key is known as status-key-1. Under MVS, the file has been created if the open mode is I-O or EXTEND. http://www.simotime.com/vsmfsk01.htm There is more to making the Internet work for your company's business than just having a nice looking WEB site.

For files with variable-length records the minimum and maximum record lengths for the actual file may not match the minimum and maximum record lengths used by the program 41 An OPEN File Status 90 In Cobol Community Help: VSAM File Error Codes - Consolidated error code listing Share your own experience View front page Here is a consolidated list of possible mainframe VSAM file error codes and Here is a consolidated list of possible mainframe VSAM file error codes and their meaning: File Status Key (status keys 1 and status keys 2) 0 error code means "succcessfull completion"0 Usually, it may come when file was not closed.           for example, Comments Sign in|Recent Site Activity|Report Abuse|Print Page|Powered By Google Sites Home Forums ANNOUNCEMENTS Site Announcements Suggestions & Feedback APPL

Vsam File Status 97

In most installations, this is not the common practice. https://www.tutorialspoint.com/vsam/vsam_file_status.htm You have reached the end of the file. 12 Attempted to open a file that is already open. 13 File not found. Vsam File Status 92 While Writing ermanent I/O Error ermanent I/O Error - Record outside file boundary PEN, but file not found PEN with wrong mode ried to OPEN a LOCKed file PEN failed, conflicting file attributes Vsam File Status 46 Comments or Feedback This document was created and is copyrighted and maintained by SimoTime Technologies.

Company Overview Founded in 1987, SimoTime Technologies is a privately owned company. http://gmailpush.com/file-status/vsam-file-error-code-90.html Possible violations are:The EXTEND or OUTPUT phrase was specified but the file would not support write operations.The I-O phrase was specified but the file would not support the input and output Software Agreement and Disclaimer Permission to use, copy, modify and distribute this software, documentation or training material for any purpose requires a fee to be paid to SimoTime Technologies. StatusKey-1Description by Group 0Successful Completion or non-terminal condition that may be acceptable to continue processing. Vsam File Status 93

This can be caused by issuing a read after the end-of-file has been reached during sequential processing. 9149 95 Wrong open mode or access mode for REWRITE/ DELETE. 9150 96 Program Internet Access Required The following links will require an internet connection. Books on Vsam Vsam Manuals / Tutorials VSAM error code, VSAM file status, VSAM/QSAM status key, abend codes error code, file status, status key, VSAM open error, QSAM open error, VSAM http://gmailpush.com/file-status/vsam-file-error-code-35.html Top of Page | Home | Books for Computer Professionals | Privacy | Terms | | Site Map and Site Search | Programming Manuals and Tutorials | The

In this case, the physical size of the new record is allowed to be smaller than that of the record being replaced. 46 A sequential READ operation has been tried on It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. This key value applies to an indexed file in which the alternate key has been declared 'UNIQUE'.2 - 3 An attempt was made to randomly access a record that does not

You can check them in the same way that you check VSAM files.

About Us MAINFRAMESTECHHELP is a mainframe community and created to provide the help for all mainframes related technical needs for the people who are all in need. For relative and indexed files in the sequential access mode, the last input- output statement executed for the file prior to the execution of a DELETE or REWRITE statement was not Check the ASSIGN(EXTERNAL) directive and possible environment variable setting for the COBOL file name. 9005 05 Illegal device specification. 9006 06 Attempt to write to a file opened for input. 9007 Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate

The number of significant digits in the relative record number is larger than the size of the relative key data item described for that file. Facebook Twitter Googleplus Youtube Reddit pinterest The request cannot be fulfilled by the server The American Programmer Home Books on Mainframe Programming Mainframe Manuals and Tutorials System Abend The ascending key requirements of successive record key values has been violated or the prime record key value has been changed by a COBOL program between successful execution of a READ check my blog Explore the non-Relational Data Connection for more examples of accessing methodologies and coding techniques for Data Files and VSAM Data Sets.

Too many files open simultaneously (Micro Focus). 15 Too many indexed files open (Micro Focus). 16 Too many device files open (Micro Focus). 17 Record error: probably zero length (Micro Focus). Or, a sequential WRITE statement was attempted for a relative file and the number of significant digits in the relative record number was larger than the size of the relative key Also, check to see if the path to the file concerned exists (Micro Focus). 14 Relative files only. Possible causes:Attempting to write beyond the externally defined boundaries of a file.Attempting a sequential WRITE operation has been tried on a relative file, but the number of significant digits in the

I know it is logic error, but what does it mean.. In this case, the physical size of the new record is allowed to be smaller than that of the record being replaced.4 - 6 A sequential READ statement was attempted on If the open mode is I-O, the file has been created. This does not apply to VSAM sequential files.

Whether you want to use the Internet to expand into new market segments or as a delivery vehicle for existing business functions simply give us a call or check the web IMS DB Tutorial CICS Tutorial IDCAMS Tutorial Contact Us [email protected] Facebook Twitter Googleplus Youtube © Copyright 2014. Downloads & Links This section includes links to documents with additional information that are beyond the scope and purpose of this document. Possible causes:Attempting to WRITE or REWRITE a record that is larger than the largest, or smaller than the smallest record allowed by the RECORD IS VARYING clause of the associated file.Attempting

It's about the business of doing business and looking good in the process. Explore How to Obtain and Display the File Status after attempting to access a data file or VSAM data set. For line sequential files this refers to the physical size of the record, that is after space removal, tab compression and null insertion. File status 0 is returned.0 - 7 For a CLOSE statement with the NO REWIND, REEL/UNIT, or FOR REMOVAL phrase or for an OPEN statement with the NO REWIND phrase, the

Hi, Can some one elaborate me what is the file status 92 , while reading the vsam file. Other possible causes are: 1. VSAM Open error codes 136(88) Not enough Virtual-Storage Space is available for Work Areas, Control Blocks, or Buffers. 144(90) An uncorrectable I/O error occurred while VSAM was Reading or Writing a Indicates a sequence error.

The second character is known as status-key-2 additional detail. We have a team of individuals that understand the broad range of technologies being used in today's environments. The documentation and software were developed and tested on systems that are configured for a SimoTime environment based on the hardware, operating systems, user requirements and security requirements. Note:A SimoTime License is required for the items to be made available on a local system or server.