Home > File Status > Vsam File Error Code 90

Vsam File Error Code 90

Contents

Also, check to see if the path to the file concerned exists (Micro Focus). 14 Relative files only. MrSpock Global moderator Posts: 811Joined: Wed Jun 06, 2007 9:37 pmLocation: Raleigh NC USA Hasthanked: 0 time Beenthanked: 2 times Top Re: ABENDU4038 IN READING A FILE by Robert Sample Other possible causes are: 1. An attempt was made to write or rewrite a record that is larger than the largest, or smaller than the smallest record allowed by the RECORD IS VARYING clause of the this content

If opened I-O the file was created. Maybe empty file opened as I-O. (Open) 91Password failure. (Open) 92File already open. (Open) File not open. (Close, Start) File not open or already at end. (Read, Read Next) File not Check the ASSIGN(EXTERNAL) directive and possible environment variable setting for the COBOL file name. 9005 05 Illegal device specification. 9006 06 Attempt to write to a file opened for input. 9007 Thanks, Smith Back to top SmithBeginnerJoined: 07 Apr 2005Posts: 13Topics: 5 Posted: Tue Sep 06, 2005 1:57 pm Post subject: Kolusu, Forgot to add that, the SYSOUT says it is abending

File Status Code 90 In Cobol

Refer to the section for Status-Key-1 being equal to "0" for additional information based on Status-Key-2. 1End of File, attempting to read beyond the end of the file. The status code was 90. If you open a QSAM/VSAM file in a multithreaded application, you must close it from the same thread of execution from which the file was opened. nn will be set to an operating system status value. (Any) 34Disk full for sequential file or sort file. (Write, Sort) 35File not found. (Open, Sort) 37,01File being opened is not

The file has been successfully opened, but indexed database file created with unique key; or (2) Duplicate keys not specified in COBOL program, and indexed database file created allowing duplicate keys. Attempt has been made to store a record that would create a duplicate key in the indexed or relative file OR a duplicate alternate record key that does not allow duplicates. G Output exception to device or session. File Status 90 In Cobol 400 CPF5003 P The file has been opened successfully, but it contains null-capable fields and the ASSIGN clause does not specify ALWNULL and device-type DATABASE.

M Last record written to a subfile. The INPUT phrase was specified but the file would not support read operations. The documentation and software were developed and tested on systems that are configured for a SimoTime environment based on the hardware, operating systems, user requirements and security requirements. http://www.mvsforums.com/helpboards/viewtopic.php?t=4782 I'd think it would just be:Select allFILE-CONTROL.

Why it is abending? Cobol File Status Extended File Status, nnn-xx The first character of the File-Status-Key is known as status-key-1. H ACQUIRE operation failed. Refer to the section for Status-Key-1 being equal to "4" for additional information based on Status-Key-2. 9Implementor Defined, Many vendors take advantage of the x"00' to x'FF' (or 0-255) binary value.

Vsam File Status 90 In Cobol

Explore The ASCII and EBCDIC Translation Tables. http://publib.boulder.ibm.com/iseries/v5r1/ic2924/books/c0925392642.htm CPF5001, CPF5025, CPF5183. 7 The execution of a READ or START statement was attempted on a file not open in the input or I-O mode. 8 The execution of a WRITE File Status Code 90 In Cobol D Record is locked CPF5027, CPF5032. Status Code 90 Netbackup The first character of the File-Status-Key is known as status-key-1 and defines a group or category.

We are reading the file using an alternate index (actually Start ..Read Next command) and it is here where it abends with 90 status code Thanks, Smith Back to top vkphaniIntermediateJoined: http://gmailpush.com/file-status/vsam-file-error-code-37.html SimoTime Services has experience in moving or sharing data or application processing across a variety of systems. Refer to the section for Status-Key-1 being equal to "1" for additional information based on Status-Key-2. 2Invalid Key, an attemprt to access a file failed because the requested key is not The minimum record length specified by the program is less than the minimum record length required for the file. File Status 90 In Cobol While Writing

Thanks, Phantom Back to top vkphaniIntermediateJoined: 05 Sep 2003Posts: 483Topics: 48 Posted: Wed Sep 28, 2005 1:27 am Post subject: Thanks for the info Phantom. FD STUDENTFILE RECORDING MODE IS F LABEL RECORDS ARE The intent is to provide changes as the need arises and in a timeframe that is dependent upon the availability of resources. http://gmailpush.com/file-status/vsam-file-error-code-35.html Comments or Feedback This document was created and is copyrighted and maintained by SimoTime Technologies.

For the COBOL environment if the FILE STATUS clause is specified in the FILE-CONTROL entry, a value is placed in the specified status key (the 2-character data item named in the File Status In Cobol Example The value indicates the status of that request. Possible causes:Attempting to write beyond the externally defined boundaries of a file.Attempting a sequential WRITE operation has been tried on a relative file, but the number of significant digits in the

In output dataset it was mentioned There was an unsuccessful OPEN or CLOSE of file SFILE in program TSTF01 at relative location x’03DC’.

I thought it is some logical error, but when i restarted the job I got a file status of 90 in another key (not the same key as before). Company Overview Founded in 1987, SimoTime Technologies is a privately owned company. Level check error. How To Resolve File Status 46 In Cobol Or, a sequential WRITE statement was attempted for a relative file and the number of significant digits in the relative record number was larger than the size of the relative record

CPF4380. [ Top of Page | Previous Page | Next Page | Table of Contents | Index ] The request cannot be fulfilled by the server Back to COBOL Topics Index Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate Depending on whether the VSAM is held up by other jobs, your job might end up in Contention but not in File Status 90. check my blog C Acquire failed; session was not started.

Refer to the section for Status-Key-1 being equal to "9" for additional information based on Status-Key-2. CPF502B U Cannot complete READ PRIOR because records are left in block from READ NEXT, or vice versa.