Home > File Status > Vsam Close Error

Vsam Close Error

Contents

VSAM is not able to resolve the conflict. Return Code=08 Action=Request VSAM detected a record out of sequence in a key-sequenced or relative-record file (possibly a duplicate key or record number). Too many files open simultaneously (Micro Focus). 15 Too many indexed files open (Micro Focus). 16 Too many device files open (Micro Focus). 17 Record error: probably zero length (Micro Focus). The file is an ESDS being opened in CNV mode. this content

This condition indicates that an attempt has been made to write beyond the externally defined boundaries of a sequential file. 35 An OPEN operation with the I-O, INPUT, or EXTEND phrases PROGRAMMER ACTION: Recompile the progam with a larger work area specified. PROGRAMMER ACTION: Print the dump from SYSDMP. (Refer to VSE/VSAM Programmer's Reference for interpretation of the IDUMP output.) Contact your IBM Support Center, and make the program listing, console log, and Save the dump you obtain and the SYSLOG output for later problem determination.

Vsam Return Codes

PROGRAMMER ACTION: Probable job control error. Instruct the operator to ensure that the device on which the volume mounting is done is in "up" status and unreserved before replying `NEWPAC'. This can also happen when a sequential file is open for input and an attempt is made to open the same file for output. (Micro Focus only). 34 PROGRAMMER ACTION: Change your program to use managed SAM to access the file, or change the DLBL statement to specify a file other than SAM ESDS.

Use this when there is RC 12 in vsam-extended-return-code 004 Read error on data 008 Read error on index 012 Read error in sequence set 016 Write error on data X'38' 056 Return Code=08 Action=Request An error occurred during dynamic assignment of a volume. Either there is not enough space left to make the secondary allocation or you attempted to increase the size of a data set while processing SHROPT=4 and DISP=SHR. 036(24) Key Ranges Vsam File Status 93 ARG parameter was not specified when required.

For files with variable-length records the minimum and maximum record lengths for the actual file may not match the minimum and maximum record lengths used by the program PROGRAMMER ACTION: Change your job control EXTENT statement(s) to specify logical unit(s) which are valid for the partion and rerun the job, or remove the logical unit specification from the EXTENT OPEN with RESET was specified in the ACB and the file is being accessed by another ACB. All Rights Reserved.

X'74' 116 Return Code=04 Action=OPEN You tried to open a file that was not successfully closed the last time it was opened for output. Vsam File Status 97 Run the Catalog Check Service Aid against the entire catalog; it will indentify catalog errors for you. X'B4' 180 Return Code=08 Action=OPEN An error occurred in opening a catalog or CRA. A sequential READ statement was attempted for a relative file, and the number of significant digits in the relative record number is greater than the size specified for the relative key

Vsam File Status 39

For a CLOSE statement with the NO REWIND, REEL/UNIT, or FOR REMOVAL phrase or for an OPEN statement with the NO REWIND phrase, the referenced file was on a non-reel/unit medium. navigate to this website For relative and indexed files in the sequential access mode: The last I/O statement executed for the file, before the execution of a DELETE or REWRITE statement, was not a READ Vsam Return Codes DISP=NEW was specified for an input file. File Status 37 In Vsam PROGRAMMER ACTION: Try to find the reason for the nonavailabilty of the volume or extent.

During implicity deletion, the operator will be requested to authorize deletion if the expiration data previously specified for the file has not passed. http://gmailpush.com/file-status/vsam-error-90.html X'D0' 208 Return Code=08 Action=Request For SHAREOPTIONS(4), a lock required for update or insert processing is held in exclusive control by another ACB. Refer to the section for Status-Key-1 being equal to "9" for additional information based on Status-Key-2. Return Code=08 Action=Request No record found. Vsam File Status 92

Save the dump you obtain and SYSLOG output for later problem determination. X'70' 112 Return Code=08 Action=Request The length of the generic key specified for the RPL is too large or is equal to zero. X'60' 096 Return Code=04 Action=OPEN The file to be opened for input was found to be unusable because catalog recovery for this file failed. http://gmailpush.com/file-status/vsam-35-error.html Make sure that your DLBL statement specifies a file-id which you know is a SAM ESDS.

X'C4' 196 Return Code=08 Action=OPEN Access to data was requested via an empty alternate index. File Status In Cobol Example Return Code=08 Action=Request For SHAREOPTIONS(4), the file size is too large for the control area size. PROGRAMMER ACTION: This access to the data is allowed, but there are errors in the catalog structure that you should find.

This includes the smallest thin client using the Internet and the very large mainframe systems.

The operand must be specified. You are allowed to process the file, and managed-SAM will pass control to the EOFADDR routine upon encountering the file GET marco. X'32' 050 Return Code=08 Action=OPEN One or more VSAM processing modules cannot be loaded because either the GETVIS area or the partition is too small. Vsam File Status 90 X'68' 104 Return Code=04 Action=OPEN The timestamp of the volume on which the file is stored is lower than the system timestamp in the file's catalog entry.

Possible causes for this error code are: An attempt to get virtual storage failed An I/0 error occurred while VSAM was reading the VTOC An extent block is not availabe in A sequential READ operation has been tried on a file open in the INPUT or I-O mode but no valid next record has been established because: The preceding READ statement was Once the fee is received by SimoTime the latest version of the software, documentation or training material will be delivered and a license will be granted for use within an enterprise, check my blog In most installations, this is not the common practice.

The DTF implies a CI format file but the file is NOCIFORMAT. The Recording Mode is Variable or Fixed or not defined the same as when the file was created. 3. X'E8' 232 Return Code=08 Action=OPEN ACB MACRF = RST (reset) was specified for a non-reusable file and that file is not empty.