Home > Error Code > Vita Spa Error Code Ps

Vita Spa Error Code Ps

Contents

It is a Gulf Coast Spa with a 10/12/2016 10/12/2016 JACUSTOMER-27j3luit- I just replace the control board on my MasterTemp 250, and 10/5/2016 10/5/2016 JACUSTOMER-x0uwnnmp- I have a 2003 cal spa SnS = Sensors out of balance. Used hot tub tonight, ran jets, when I went to put cover back on I noticed FLO code back on. BUT, you helped me figure out what part I needed for my hot tub and I really appreciated that:) I will highly recommend your website to anyone needing parts/and or service!!" have a peek here

To print the manual completely, please, download it. SESH Sensor Short Circuit SESH Sensor short, nonfunctional. It wants to - I keep hearing ‘clicking' as if something's trying to engage - but all that happens is that the temp indicator keeps rising to the point that the Heater deactivated * FL1 : Water flow problem, pressure switch malfunction. their explanation

Hot Tub Error Codes

I am out of options….I did make sure I went in to Standard mode… any suggestions? Anyway not positive but possible number 2 pump never worked this year, but I think LF and dry started after leaves were in tub. Heater deactivated Sn2 Temperature sensor fault Sn3 Temp sensor failure SnS Sensors out of balance. Water temp has reached 118ºF.

Sign in 3 1 Don't like this video? You can leave a response, or trackback from your own site. Posts: Popular In-ground Pool Heaters: Electric vs. Great Lakes Hot Tub Error Codes There are a couple of common causes for flow errors in hot tubs; low water level, dirty filters, clogged circulation pumps, and bad flow sensors.

Tu Temperature Set Celsius Tu Temperature Set Fahrenheit dr Inadequate water detected in heater. SpaBrothers 4,036 views 0:59 Balboa Legacy Systems Series - Pressure Switch Calibration - For non M7(TM) systems - Duration: 4:17. I would like to know what the board is telling me. https://spacare.com/spasideerrorcodes.aspx A lot of times the customer won't know the tub is giving them a low flow error, and only that the tub has not been heating and the temperature is down

OH = Over heat. Hot Tub Error Code Oh Sundance Spa or Hot Tub Control Systems: ILOC = Interlock failure - possible pump or ozone spike FLO = Pressure switch malfunction or Flow switch malfunction (system specific)Hold = Panel buttons I topped off the water, both were process of elimination and not required. Spa Builders Spa Side Error Codes Sn1 = Nonfunctional high temperature sensor.

Balboa Hot Tub Error Codes

Call Electrician if it will not start.

Replace Pressure Switch Replace Sensor Replace Sensor PAGE 33 Previous page Next page 1...333435363738394041 Also See for Vita Spa L100 Vita Spa L100 SERIES Owner's Manual 37 pages Related Hot Tub Error Codes Phil Dissek June 6, 2016 at 8:54 pm I have a 2010 Marquis Rondevous spa and I just replaced the impeller (after changing the water and filter). How To Fix Flo Error Hot Tub cohesive8 3,752 views 9:31 Pressure switch - Duration: 1:25.

If display shows only this message (blinking) spa is shut down * HFL : Substantial difference between temperature sensors detected. http://gmailpush.com/error-code/vita-spa-error-code-h1l1.html No action is necessary * PnL : Communication between the panel and circuit board is faulty * ---- : "Watchdog" (spa is deactivated) A problem has been detected * Sn1 : I be the PC board needs to be replaced.-Jay admin October 10, 2015 at 7:34 pm Hi Pete,Sounds like either bad sensors or a bad PC board.-Jay admin October 10, 2015 Spa may be partially deactivated or low speed pump (and air blower if equipped) may activate to lower temp OHH Overheat. Gecko Spa Pack Error Codes

Check for proper spa water level and ensure pump is primed. One sensor has detected 118º. toby May 15, 2015 at 2:15 pm I have a belize 3000L hot tub my error codes is LOC and FLC at the same time.I did have a flo code as Check This Out Anyway don't see a third circulation pump.

You can follow any responses to this entry through the RSS 2.0 feed. Coast Spa Error Codes The equipment stays on until the sensors detect that the spa temperature has risen to within 20 degrees of the set temperature. Or you can just order a new pressure switch (probably about $30-$50) and swap it out to see if that works.

Flo = Improper flow or pressure switch malfunction Cool = Water temp 20° below set point ICE = Potential freeze condition has been detected Sn1 = Hi-limit sensor malfunction Sn3 =

In rare cases (usually warmer climates), the circulation pump may also cause overheating. PSoH = Pressure switch open with high pump. Snb Sensor plugged into jack B is not working. Morgan Spa Error Codes System will restart when temp.

Heater disabled but spa operational. If I spray into the pump with a garden hose, there is warm water entering the tub. This indicates a persistent flow problem The heater is shut down while all other spa functions continue to run normally. http://gmailpush.com/error-code/vita-spa-error-code-ice.html Alphabetical Error Code List * * * (3 flashing dots under temp display) Flow/Pressure switch either Open or Closed Circuit * * * (as above, plus illuminated red LED on PCB)

If display shows only this message (blinking) spa is shut down Sna Spa is shut down. Heater disabled but spa operational. * PSoC : Pressure switch open with circulation pump. * PSoL : Pressure switch open with low pump. * PSoH : Pressure switch open with high Spa has shut down. Heater is shut down, but other spa functions run normally.

Low speed pump and heater will activate until spa reaches 65ºF * OH : High temperature condition, has reached 110ºF. Heater disabled but spa operational. You can also have something called a pressure switch located on your heater element which does the same thing. The following is a list of most probable causes of this message.

Check power connections and rerun diagnostic t e s t Replace oz o n a t o r Check plug for Pump 1 Check plug for Pump 2 Check topside connection I believe I have two problems anyway. System will restart when temp. SnH Hi Limit circuit open or faulty SnS Sensors out of balance, reporting different results SnT Temperature sensor fault, circuit open or faulty SP-F1,F2 or F3 Fuse 1,2 or blown SP-HR

Std = Spa operating in Standard Mode. Any ideas? OH = High temperature condition, has reached 110ºF. Spa is shut down.

ILOC = Interlock failure - possible pump or ozone spike. (---) =Unknown water temperature. (Displays when first powered up after refill). HOT Circuit Board temperature has exceeded acceptable limit (air blower may be on) HiLi, HLEr Water temperature above acceptable range Hold Panel buttons pressed too many times too quickly I CE2 If it does you know you need a new pressure switch.let me know how that works.-Jay Howard July 31, 2014 at 7:32 am I have a Jacuzzi Model J-280 and I Hold = Panel sensors have been pressed too many times in a short period of time.HOT = Circuit Board temperature has exceeded acceptable limit.ICE = Freeze protection.

ICE = Freeze protection.